4.2 Charge voltage
- Recommended charge voltage: 14V-14,4V per battery (14,2V recommended),
- Absorption time: 2 hrs for a 100% charge, or a few minutes for a 98% charge.
- Maximum charge voltage: 14,4V resp
- Recommended storage/float voltage: 13,5V
- Batteries must be regularly (at least once every month) charged to 14V (max. 14,4V) in order to fully balance the cells.
There is quite a difference between the two. So by applying the Victron recommendations to the Balmar program this is what I came up with:
- Start delay is the same
- High Voltage limit: I would make it 14.2 (even though 14.4 is allowed why push the limit if 14.2 is recommended)
- Compensation limit: 14.2 (There should be no temperature compensation, see last line above)
- Bulk voltage 14.2
- Absorption voltage 14.2
- Absorption time * see note below but keep as is for now
- Float voltage 13.5
- Max Bat temp leave as is
- Max alt temp leave as is
- Batt temp compensation leave as is (zero)
*You can only define the minimum absorption time, not the
max absorption time. You may have to tweak this a bit. The purpose
of the absorption time is to equalize the cells. You just have to do that
from time to time, so if you go to a dock the MultiPlus does it for you and you
don’t necessarily have to do it on the water. If you never go to the dock
you might have to monitor it a few times to see what happens when you leave it set
to 18 minutes
1 Comments
Ed
I’ve read that lithium batteries should not have any float time. So having the mc614 - shouldn’t we change the minimum float time To 0 and the maximum float time to 0 as well ?