Expected availability beginning Mid September 2024
We see this as providing backup power for small to medium devices in the event of a power outage. Medical devices, security systems, and computer equipment would be ideal uses. You can also use it to power a computer or TV and maybe a small microwave. The output is a pure sine wave with 1200 VA at 25 deg C, the built in transfer switch can act so fast it makes the device act as an uninterruptible power supply. The built in charger can charge the batteries at up to 50 amps when external power is available. This MultiPlus shares the same connectivity as the larger units, it can be programmed with a computer using a Mk3 USB interface and Victron Connect. It can be set up for whatever kind of batteries you need to use. It can be connected to a Cerbo GX for remote monitoring using the Victron VRM.
MultiPlus 12/500/20 - 120Vac
Multiplus 12/1200/50 - 120Vac
PowerControl / PowerAssist
Yes / No
Yes / Yes
Transfer switch
16A
INVERTER
Input voltage range
9.5 - 17Vdc
Output voltage
120Vac ± 2%
Output frequency(1)
60Hz ± 0,1%
Cont. output power at 25°C (77°F) (3)
500VA
1200VA
Cont. output power at 25°C (77°F)
430W
1000W
Cont. output power at 40°C (104°F)
400W
900W
Cont. output power at 65°C (149°F)
300W
600W
Peak power
2400W
Maximum efficiency
90%
93%
Zero-load power
6W
10W
Zero-load power search mode
2W
3W
CHARGER
AC Input voltage range
95 - 140Vac
AC input frequency range
45 - 65Hz
Charge voltage 'absorption'
14.4V
Charge voltage 'float'
13.8V
Storage mode
13.2V
Charge current house battery (4)
20A
50A
Charge current starter battery
1A
Battery temperature sensor
Yes
GENERAL
Programmable relay (5)
Protection (2)
a – g
Operating temperature
-40 to +65°C (-40 to + 140°F), fan assisted cooling
Humidity
Maximum 95%, non-condensing
ENCLOSURE
Material & colour
Steel/ABS, blue RAL 5012
Protection category
IP 21
Battery-connection
16 mm²
35 mm²
230V AC-connection
G-ST18i connector
Weight
4.4kg
8.2kg
Dimensions (h x w x d)
311 x 182 x 100 mm
406 x 250 x 100 mm
STANDARDS
Safety
EN-IEC 60335-1, EN-IEC 60335-2-29, EN 62109-1
Emission / Immunity
EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3
IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3
Road vehicles
ECE R10-4
1) Can be adjusted to 50Hz
2) Protection
a. Output short circuit
b. Overload
c. Battery voltage too high
d. Battery voltage too low
e. Temperature too high
f. 120Vac on inverter output
g. Input voltage ripple too high
3) Non-linear load, crest factor 3:1
4) Up to 25°C (77°F) ambient
5) Programmable relay which can be set for:
general alarm, DC under voltage or generator start/stop signal function
AC rating: 230V/4A
DC rating: 4A up to 35Vdc, 1A up to 60Vdc