MultiPlus-II
12/3000/120-50 2x 120
24/3000/70-50 2x 120
PowerControl & PowerAssist
Yes (on L1 input)
Transfer switch
50 A
Maximum AC input current
50 A (each leg)
INVERTER
DC Input voltage range
9,5 – 17 V
19 - 33 V
Output when in inverter mode
Output voltage: 120 VAC ± 2%
Frequency: 60 Hz ± 0,1% (1)
Cont. output power at 25°C (3)
3000 VA
Cont. output power at 25°C
2400 W
Cont. output power at 40°C
2200 W
Cont. output power at 65°C
1700 W
Maximum apparent feed-in power
2500 VA
Peak power
5500 W
Maximum efficiency
93%
94%
Zero load power
15 W
11 W
Zero load power in AES mode
10 W
8 W
Zero load power in Search mode
4 W
Maximum output current
60A peak, 50Arms for 1sec.
CHARGER
AC Input
Split phase: 180-280 VAC 45 – 65 Hz
Single phase: 90-140 VAC 45 – 65 Hz
Charge voltage 'absorption'
14.4 V
28.8 V
Charge voltage 'float'
13.8 V
27.6 V
Storage mode
13.2 V
26.4 V
Maximum battery charge current (4)
120 A
70 A
Battery temperature sensor
Yes
GENERAL
Auxiliary output
Yes (50 A)
External AC current sensor (optional)
100 A
Programmable relay (5)
Protection (2)
a – g
VE.Bus communication port
For parallel and three phase operation, remote monitoring and system integration
General purpose com. port
Yes, 2x
Remote on-off
Operating temperature range
-40 to +65°C (-40 - 150°F) fan assisted cooling
-40 to +60°C (-40 - 140°F) fan assisted cooling
Humidity (non-condensing)
max 95%
ENCLOSURE
Material & Colour
Steel, blue RAL 5012
Protection category
IP22
Battery-connection
2x2 M8 bolts
2 M8 bolts
120/240 V AC-connection
Screw terminals 21 mm² (4 AWG)
Weight
22 kg (48 lb)
Dimensions (hxwxd) mm
578 x 275 x 148
(23 x 11 x 6 inch)
STANDARDS
Safety
EN-IEC 60335-1, EN-IEC 60335-2-29, UL 458
EN-IEC 60335-1, EN-IEC 60335-2-29, UL 458, UL 1741
Emission, Immunity
EN 55014-1, EN 55014-2
EN-IEC 61000-3-2, EN-IEC 61000-3-3
IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3
Can be adjusted to 50 Hz
Protection key:
output short circuit
overload
battery voltage too high
battery voltage too low
temperature too high
120 VAC on inverter output
input voltage ripple too high
Non-linear load, crest factor 3:1
Up to 75°F / 25°C ambient
Programmable relay which can be set for general alarm, DC under voltage or genset start/stop function. AC rating: 120V / 4A, DC rating: 4A up to 35VDC and 1A up to 60VDC
A. o. to communicate with a Lithium-Ion battery BMS
The auxiliary output of an early production batch of this product was rated at 35A instead of 50A. This batch has serial numbers starting with HQ2107. Later batches, with 50A aux. output have serial numbers starting with HQ2114 or higher.