Skylla-IP65
12/70
24/35
Input voltage (VAC)
120 – 240
Input voltage range (VAC) (1)
90 – 265
Maximum AC input current
12
Frequency (Hz)
45-65
Power factor
0,98
Charge voltage 'absorption' (VDC) (2)
See Manual
Charge voltage 'float' (VDC) (2)
Charge voltage ‘storage’ (VDC) (2)
Charge current main batt. (A) (3)
70
35
Charge current starter batt. (A) (4)
3
4
Charge curve, lead-acid
7 stage adaptive
Recommended battery capacity (Ah)
350-700
150-350
Charge curve, Li-Ion
2 stage, with on-off control or VE.Can bus control
Temperature sensor
Yes
Power supply function
Remote on-off port
Yes (can be connected to a Li-Ion BMS)
CAN bus communication port
Two RJ45 connectors, NMEA2000 protocol
Remote alarm relay
DPST AC rating: 240 VAC/4A
DC rating: 4A up to 35 VDC, 1 A up to 60 VDC
Forced cooling
Protection
Battery reverse polarity (fuse)
Output short circuit
Over temperature
Operating temp. range
-20 to 60 °C (full output current up to 40 °C)
Humidity (non-condensing)
max 95 %
ENCLOSURE
Material & Colour
steel; blue, RAL 5012
Battery-connection
M6 bolts
Mains connection
screw-clamp 6 mm² (AWG 10)
Protection category
IP65
Weight kg (lbs)
6 (14)
Dimensions hxwxd incl. glands in mm in inches
401 x 375 x 265
(16 x 15 x 10.5)
STANDARDS
Safety
EN 60335-1, EN 60335-2-29
Emission
EN 55014-1, EN 61000-6-3, EN 61000-3-2
Immunity
EN 55014-2, EN 61000-6-1, EN 61000-6-2, EN 61000-3-3
1) Output current will gradually reduce below 110 V to 50 % @ 100 V
2) Depending upon battery type as selected in the setup menu.
3) Maximum current up to 40 °C (100 °F) ambient. Output current will reduce to 60 % at 50 °C, and to 40 % at 60 °C.
4) Depending upon state of charge of starter battery